01Electrical power
MV/LV distribution
MV switchgear, transformers, LV switchboards, selectivity.
- MV/LV transformers and switchgear
- LV switchboards and busway distribution
- Load, selectivity and coordination studies
- Reactive power compensation
Data center MEP engineering
Power, cooling and monitoring engineered as one system, from the first study to the final commissioning test.
Conceptual illustration
01Electrical power
MV switchgear, transformers, LV switchboards, selectivity.
02Electrical power
Sizing and autonomy calculation.
03Electrical power
Paralleling and synchronisation.
04Electrical power
Rated busway, tap-off units, dual-feed rack distribution.
05Cooling and HVAC
CRAC, CRAH and in-row units in N+1 or 2N redundancy.
06Cooling, plumbing and piping
Chillers, pumps, hydraulic network, free cooling.
07Monitoring and safety
Power, environment and alarm supervision.
08Monitoring and safety
Addressable and aspirating smoke detection.
One accountable team
4
MEP disciplines
Electrical power, cooling and HVAC, plumbing and piping, monitoring and safety.
5
Stages, one team
Design, supply, installation, testing and commissioning, as-built.
6
Engineering capabilities
The complete engineering chain, handled in-house.
0
Interruption
Modernisation from Tier II to Tier III with migration without interruption.
TODO: add verified company figures (team size, projects delivered, installed power).
Project formats
Manufacturers design the products. ESP designs the system around them, integrates it on site and commissions it.
Compact rooms and micro-modules, from power to monitoring.
Full MEP design, from the utility connection to the rack.
Integration and upgrade inside existing buildings.
Site design and integration of prefabricated modules.
We integrate
Conceptual drawings, not to scale.
Cooling design and integration
In every case the method is the same: heat load first, then technology choice, redundancy, airflow check and PUE.
| No. | Technology | Principle | Suited to | Diagram |
|---|---|---|---|---|
| 01 | Perimeter CRAH | Room cooling with raised floor and contained aisles. | Classic rooms | |
| 02 | In-row | Close-coupled cooling for higher-density rows. | Rows where density rises | |
| 03 | Chilled water | Chiller and dry cooler, with free cooling when the climate allows. | Larger sites | |
| 04 | DX | Self-contained units for edge sites and small rooms. | Edge sites and small rooms |
Our method
References
Modernisation from Tier II to Tier III with migration without interruption. Electrical HLD and LLD, UPS and rectifiers, busway for PODs and IT racks, monitoring, MDU room and cable trench civil works.
Engineering, project management and supervision of LV systems, BMS and SCADA design, data center and monitoring, with technical support on electrical, HVAC and medical gases.
CFO and CFA engineering: HV and LV, MV/LV transformers, distribution, lighting, grounding, CCTV, IT, telephony, fire protection and substation control.
Engineering, supply and execution of CFO and CFA works, from MV/LV transformers to fire protection.
Engineering depth
Topologies from N to 2(N+1), set and reviewed by our Uptime ATD engineer.
Load flow, short-circuit, selectivity, voltage drop, harmonics and earthing.
Heat load, cooling selection, containment, redundancy and PUE.
One coordinated 3D model: clash detection, routing and quantities.
Native or multi-vendor supervision over Modbus RTU, Modbus TCP and SNMP.
Test plans, integrated system tests and as-built records by the design team.
Design toolchain by project stage
Quality gate at every phase
CAD and BIM
AutoCAD2D layouts, schematics, as-built drawings. Used from concept to as-built.
Revit MEPcoordinated 3D model, quantities. Used from detailed design to as-built.
Navisworksclash detection, model review. Used from detailed design to construction drawings.
Electrical
ETAPload flow, short-circuit studies. Used from concept to detailed design.
Caneco · EcodialLV sizing, selectivity. Used from detailed design to construction drawings.
EPLANschematics, panel design. Used from detailed design to construction drawings.
DIALuxlighting. Used at detailed design.
Resilience and compliance
Redundancy and distribution paths derived from the Tier objective.
Every power and cooling path traced to remove single points of failure.
Checked against the Tier target for each critical component.
Signed off by our Uptime ATD-certified engineer before issue.
Standards we apply
What the Tier review checks
TODO: other certifications (for example ISO 9001) and geographic coverage.
AI and HPC
StatusA capability in preparation, not a project reference.
Rack density
50–130+kW per rack
The density that GPU clusters bring.
We follow liquid cooling, high-density power and energy storage as they mature.
Our engineers are training on AI data center design and integration.
We are preparing to integrate proven solutions with technology partners.
TODO: technology partners.
Conceptual diagram, not to scale.
Telecom infrastructure
Our Telecom & Radio division installs, modernises and maintains the sites that carry fixed and mobile traffic.
A telecom site is one installation: steel, antennas, radio units, transmission links, power and earthing, engineered to work together.
Conceptual illustration
01Radio
02Transmission
03Power and earthing
04Telecom and maintenance
Beyond the data center
Plants, hospitals and complex buildings run on the same principles as a data center: reliable distribution, controlled processes and systems that can be supervised.
MV/LV transformers, distribution panels, cable routing and grounding, sized and coordinated from load studies to commissioning.
Control system architecture, functional analysis, automation station programming, operator supervision, fieldbus and FAT.
BMS, EMS and SCADA (GTB, GTE, GTC) with protocol conversion from fieldbus to IP.
High and low current works: lighting, power, CCTV, IT and telephony, fire detection and protection.
BIM modelling of electrical systems, multidisciplinary coordination and clash detection, BOQ extraction from design models.
Ethics. Safety. Performance.
Our ethical approach is the foundation of how we operate and of long-term, trusted partnerships. We help clients succeed by mastering costs, timelines and technical requirements, and we deliver reliable, secure, high-performance installations.
Contact
Tell us about your facility, your network or your plant. We will review your requirements and identify where ESP can contribute.
Write to ESP